Key Details of InstElectric - Electricity

  • Tool to support the calculation of electrical installations that will allow the user (designer / electrician / technician) to perform electrical...
  • Last updated on
  • There have been 1 updates
  • Virus scan status:

    Clean (it's extremely likely that this software program is clean)


Enlarged image for InstElectric - Electricit…
InstElectric - Electricity 0/4

Developer's Description

Tool to support the calculation of electrical installations that will allow the user (designer / electrician / technician) to perform electrical...

Tool to support the calculation of electrical installations that will allow the user (designer / electrician / technician) to perform electrical calculations easily and quickly.

Dimensioning complete of low voltage circuits with the most frequent installation methods

Phase cable size, neutral, protective conductor

Criteria based on the admissible current of the cable, voltage drop and overcurrent protection

Designation of the most used cables.

Circuits with automatic circuit breaker until In = 4000 A (Ir rating setting), maximum fuse In = 1600 A (gG type), maximum 12 conductors parallel per phase, maximum size 630 mm

Estimate of the maximum short-circuit current (simplified method)

Forecast of loads of a building destined to houses with several sections: dwellings, common services, commercial premises/offices and garage with/without infrastructure for recharging electric vehicles

Reactive power of the capacitor bank for the compensation of the power factor (cos ) and capacity (F) of the capacitors

C/K Factor for automatic capacitor bank

Choice of installation system in the function of the circuit, cable and its situation

Power in an unbalanced three-phase system

Overvoltages due to loss of neutral conductor, earth fault and short circuit

Electricity parameters of a single-phase or three-phase (balanced)

Transformer performance

Secondary voltage of a transformer acoording to switch position

Size of trays and conduits

Conduits characteristics according to the installation method

Conversions of wire sizes (mm-awg) and conduits threads

Representation of the curves of the protections

International protection IP - IK

Parameter settings for calculations:

Constants (voltages, conductivity, temperatures, etc.) that affect electrical calculations

Protections (circuit breakers and fuses)

Selection of minimum rate for circuit-breakers with regulation and maximum cable size for multi-conductor grouping per phase

Method estimation of the reactance

Conductivity of the conductor depending on the current of the circuit (constant, according to the expected current, maximum cable temperature)

Use reduction factors by grouping cables/circuits

Use of factors of diversity/utilization

Reference documents: IEC Standards, REBT (sp), Technical Application Guide, (UE) 2016/364