Arc Flash Analytic v6.0 calculates arc incident energy, flash/shock boundaries, and hazard categories based on IEEE 1584 (2018). It also determines arc blast pressure and TNT equivalent for safety compliance.
  • Pros

    • Calculates arc incident energy, flash/shock boundaries, and hazard categories.
    • Based on IEEE 1584 2nd Edition 2018 Guide for accuracy.
    • Supports voltages from 208 V to 15,000 V three-phase.
    • No limit specified for fault clearing time parameter.
    • Calculates arc blast pressure and TNT equivalent.
  • Cons

    • Limited to three-phase electrical system calculations.
    • No explicit mention of integration with external design software.
    • Lacks detailed specifications on comprehensive reporting or data export.
    • Calculations are exclusively based on the IEEE 1584 model.

Used Arc Flash Analytic for Windows?


Explore More


Full Specifications

GENERAL
Release
Latest update
Version
6.0.1
OPERATING SYSTEMS
Platform
Windows
Operating System
  • Windows 10
  • Windows NT
  • Windows 2003
  • Windows 7
  • Windows Server
  • Windows ME
  • Windows Vista
  • Windows 2000
  • Windows 8
  • Windows 98
  • Windows XP
Additional Requirements
.NET Framework 3.5
POPULARITY
Total Downloads
1,436
Downloads Last Week
1

Report Software

Program available in other languages


Last Updated


Developer’s Description

Calculate incident energy and arc flash and shock protection boundaries in electrical equipment.
Arc Flash Analytic version 6.0 (AFA v6.0) software program has been developed based on IEEE 1584 2nd Edition year 2018 Guide for Performing Arc-Flash Hazard Calculations as an easy to use and comprehensive tool for calculating arc incident energy and arc flash boundary, for determining limited, restricted, prohibited approach boundaries and hazard risk category required by NEC / CEC and OSHA when work is to be performed on or near the energized equipment. Also, the program allows one to calculate initial pressure generated by arc blast and arc flash TNT (TriNitroToluen) equivalent.

The IEEE 1584 empirically derived model was chosen for arc flash analysis due to the model's capability to accurately account for a wide variety of setup parameters including:Voltages in the range of 208 V to 15 000 V, three-phase (line-to-line).Frequencies of 50 Hz or 60 Hz.Bolted fault current (rms symmetrical):208 V - 600 V : 500 A to 106 000 A;601 V - 15 000 V : 200 A to 65 000 A;Gaps between conductors:208 V - 600 V : 6.35 mm (0.25 in) to 76.2 mm (3 in.);601 V - 15 000 V : 19.05 mm (0.75 in) to 254 mm (10 in.);Working distances of 305 mm (12 in) or larger;Fault clearing time: no limit.Enclosure dimension limits:Maximum Height or Width: 1244.6 mm (49 in.);Maximum Opening Area: 1.549 m2 (2401 in2);Minimum Width: The width of the enclosure should be larger than four times the gap between conductors (electrodes).Electrode Configurations:VCB: Vertical conductors/electrodes inside a metal box/enclosure;VCBB: vertical conductors/electrodes terminated in an insulating barrier inside a metal box/enclosure;HCB: horizontal conductors/electrodes inside a metal box/enclosure;VOA: vertical conductors/electrodes in open air;HOA: horizontal conductors/electrodes in open air.


Download.com
Your review for Arc Flash Analytic