X

Climate tools for iOS

Developer's Description

The ultimate app for air psychometrics and evaporative cooling!What are the air characteristics given the current values of temperature and humidity? How can I calculate the mix of two air stream? What is the humidification load for my AHU? These are some of the questions this app can provide answers for, and, on top, also estimates of power saved by evaporative cooling.There are 9 functions available inside the app: AIR calculates the characteristic parameters of the air by entering 2 of the following 4 values: dry-bulb temperature (DBT), wet-bulb temperature (WBT), %rh, humidity ratio. The outputs are: dew-point temperature, specific enthalpy, density, specific volume, vapor pressure, vapor density MIX calculates the characteristics of the mixture from the properties of two air streams (DBT, WBT, %rh, W, flow rate) HUMIDIFICATION LOAD 1 calculates the humidification load based on an air current upstream of the humidifier and a set point. The outputs are: the humidification load, the flow rate of the atomized water (only in the case of adiabatic humidification) and the conditions of pre-heating HUMIDIFICATION LOAD MIX calculates the humidification load from the mixture of 2 air streams upstream of the humidifier and a set point. The outputs are: the humidification load, the flow rate of the atomized water (only in the case of adiabatic humidification), the conditions of pre-heating, the characteristics of the mixture of the two air streams upstream of the humidifier DEC (Direct Evaporative Cooling) calculates the cooling, as temperature and as power, of an air stream by the evaporation of water sprayed in it IEC (Indirect Evaporative Cooling) calculates the cooling, as temperature and as power, of a primary air stream by evaporation of water sprayed in a secondary air stream that does NOT mix with the primary stream. The primary and secondary streams pass through a cross-flow heat exchanger DEC + IEC calculates the cooling, as temperature and as power, of a primary air stream by evaporation of water sprayed both in the primary stream and in a secondary air stream. The primary and secondary streams pass through a cross-flow heat exchanger WITHOUT mixing. The secondary stream is the exhausted part of the return air. If the exhaust flow is less than the primary flow, the part of return air not exhausted is mixed with the cooled primary air after the heat exchanger. EVAPORATIVE COOLING calculates the additional heat rejected by a condenser coil/dry cooler when they are sprayed by water, assuming that water completely wets the exposed surface of the heat-rejection coil. AFTER THE AIR HUMIDIFIER IN AHU/DUCT calculates the conditions downstream of the humidifier in AHU/duct once the environments set point and internal sensible and latent loads are entered.

Full Specifications

What's new in version 4.1

new ebooks request form

General

Release June 10, 2016
Date Added April 9, 2012
Version 4.1

Operating Systems

Operating Systems iOS
Additional Requirements Compatible with: iphone4, ipad2wifi, ipad23g, iphone4s, ipadthirdgen, ipadthirdgen4g, iphone5, ipodtouchfifthgen, ipadfourthgen, ipadfourthgen4g, ipadmini, ipadmini4g

Popularity

Total Downloads 2
Downloads Last Week 0
Report Software

Related Apps

Google Chrome

Free
Google Chrome

Firefox: Private, Safe Browser

Free
Firefox: Private, Safe Browser

Truecaller - Spam Identification & Block

Free
Truecaller - Spam Identification & Block

WinZip - The Leading Zip, Unzip & RAR Tool

Free
WinZip - The Leading Zip, Unzip & RAR Tool

Get the best price on everything

Shop your favorite products and we’ll find the best deal with a single click. Designed to make shopping easier.